  1. PLC-based frequency conversion ...

    The main design task of the variable frequency towerless water supply equipment system is ...

  2. Touch screen, PLC and ...

    In the field of variable frequency automatic water supply equipment control, programmable control ...

  3. Secondary water supply for high-rise ...

    Cloud control is very important for the Internet of secondary water supply devices ...

  4. Constant pressure inverter water supply ...

    Companies such as constant-pressure variable-frequency water supply devices are called "...

Contact Us
Search Search
Your location: 彩宝贝 > News Center > Industry News >
Combined application of touch screen, PLC and frequency converter in variable frequency automatic water supply equipment
Time: 2020-02-07 15:31 Source: win of Water: Water factory in winning hits: Times
Combined application of touch screen, PLC and frequency converter in variable frequency automatic water supply equipment


The secondary pressurization pump room under the smart water system has a cleaner, energy-saving, intelligent frequency-controlled automatic water supply equipment. Relying on the highly efficient Internet of Things, in the dispatch center, you can view the water supply information such as the water quality, water pressure, flow rate, and water tank level of the secondary booster pump house in real-time in a refined and dynamic visual way. Real-time monitoring and control of the operation status of all equipment such as the water supply system, water supply system, sewage system, and security system in the pressure pump room. During the operation of the variable frequency automatic water supply equipment system, an intelligent alarm system will be triggered as soon as a failure occurs, and it will be fed back to the staff of the dispatching center in real time, and the system's fault information can be intelligently analyzed through the smart water service platform. Smart Water's secondary booster pump room also has an intelligent water distribution system. Based on powerful water data, intelligently analyzes the water consumption curve of the community, so as to intelligently replenish water in an efficient and reasonable manner, which not only reduces the pressure of the entire municipal pipe network's water supply capacity, but also greatly Reduced energy consumption and brought better water services to users.
In the field of variable frequency automatic water supply equipment control, the programmable controller (PLC) has always played an important role. With the country's increased investment in the frequency conversion automatic water supply equipment industry, the level of automation of water plant operation has been continuously improved, and the application of PLC in the frequency conversion automatic water supply equipment industry has gradually increased. The use of the touch screen in conjunction with PLC makes the application of PLC more flexible. At the same time, it can set parameters, display data, and describe the automation process with animations, making the application of PLC visual.
Frequency conversion automatic water supply has become a mainstream in the water supply industry, and it is an important means to ensure that the water supply network is in a constant pressure state. The modern network communication function of modern inverters provides necessary support for synchronous operation of motors, centralized remote control and online monitoring. The touch screen connected to the PLC can make the control more visual and intuitive, and the operation is simpler and more convenient.
The frequency conversion automatic water supply equipment uses PLC, touch screen and frequency converter in combination to control the frequency converter by means of communication to achieve frequency conversion constant pressure water supply.
2.Inverter automatic water supply system structure
The frequency conversion automatic water supply equipment system is mainly composed of PLC, inverter, touch screen, pressure transmitter, power and control lines, and pump unit. Users can understand and control the operation of the system through the touch screen, and can also understand and control the operation of the system through the indicators and buttons on the panel of the control cabinet, and the switch. Through a pressure transmitter installed on the outlet pipe network, the outlet pressure signal is converted into a 4-20mA or 0-10V standard signal and sent to the built-in PID regulator of the PLC. The PID operation is compared with a given pressure parameter to output the operating frequency. To the inverter. The frequency conversion automatic water supply equipment control system uses the inverter to control the speed of the water pump to adjust the water supply. According to the different water consumption, the PLC frequency output gives the operating frequency of the inverter to adjust the speed of the pump to achieve constant pressure water supply. The internal program set by the PLC drives the switching output of the I / O port to switch the AC contactor group, so as to coordinate the number of pump motors in operation, and complete the start-stop, frequency conversion and power frequency switching of the motor. By adjusting the number of motors put into operation and controlling the frequency conversion speed of one motor in the motor group, the working pressure of the system pipe network is always stable, and the purpose of constant pressure water supply is achieved.
3. Working principle of variable frequency automatic water supply equipment
Frequency conversion automatic water supply equipment system has two operation modes: manual and automatic. In the manual mode, the pump operation is controlled by the touch screen or the start and stop buttons on the control cabinet, and the start and stop of the 1 # ~ 3 # pumps can be controlled according to the needs. This mode is mainly used for equipment debugging, automatic failure and maintenance. During automatic operation, the 1 # pump is used for variable frequency operation, and the output frequency of the inverter rises from 0HZ. At the same time, the PID regulator compares the received signal with a given pressure to the inverter for control. If the pressure is not enough, the frequency will rise to 50HZ, and the program set by the PLC will drive the output of the I / O port to switch the AC contactor group, so that the 1 # pump frequency is quickly switched to the industrial frequency, and the 2 # pump frequency is started. If the pressure still does not reach the set pressure, then the 2 # pump is switched from frequency conversion to industrial frequency, and the 3 # pump is started with frequency conversion; if the water consumption is reduced, the PLC control starts to cut off from the first pump, and at the same time, the system is stabilized according to the PID adjustment parameters During operation, always maintain the pressure of the pipe network.
If there is a momentary power outage, the system will be shut down. After the power supply returns to normal, it will be manually started and the system will automatically return to the initial state and start operation. The automatic frequency conversion function is the most basic function of the system. The system automatically completes the entire operation process of starting, stopping and circulating frequency conversion of multiple pumps.
4.Setting the parameters of the inverter automatic water supply equipment
The communication parameters of PLC, touch screen and inverter must be set correctly before communication. This system is defined as Modbus protocol, baud rate is 9600, data bit is 8, no parity, stop bit is 1. In addition to setting the communication parameters of the inverter, the “free stop” must be enabled to protect the motor.
5.PLC control system of variable frequency automatic water supply equipment
This system uses intelligent PLC, relay output, and PLC programming uses Mitsubishi PLC's special programming software. The software provides a complete programming environment for offline programming, online connection and debugging. In order to improve the cost-effectiveness of the entire system, the system uses switching inputs and outputs of a programmable controller to control the start and stop of the motor, automatic input, regular switching, frequency conversion of the water pump, and fault alarm, etc., and it is given by the built-in PID of the PLC. Motor's speed, set pressure, frequency, current, voltage and other analog signal quantities.
In the past, when the water pressure is high, the frequency conversion constant pressure water supply system usually stops the frequency conversion pump, and then the frequency converter is switched to the power frequency running pump for adjustment. This switching method is theoretically more advanced than the direct switching of the power frequency, but it is easy to cause frequent start and stop of the pump set, thereby reducing the service life of the equipment. In the energy system, the operation mode of directly stopping the power frequency pump is used, and at the same time, it is quickly adjusted by the frequency converter. As long as the parameters are set properly, the pump unit can be switched without impact, the water pressure transition is smooth, and the water pressure is effectively prevented. Large-scale fluctuations and short-term water shortage when the water pressure is too low have improved the quality of water supply.
The frequency conversion automatic water supply equipment adopts the combination of PLC and inverter, and the system runs smoothly and reliably, realizing the unmanned full-automatic cycle cutting pump and frequency conversion operation, ensuring the optimal operation efficiency of each pump and the stable operation of the equipment. The smooth start eliminates the high current impact of starting. As the average speed of the pump is reduced, the service life of the pump can be extended, and the water hammer effect during startup and shutdown can be eliminated. Through the configuration screen on the touch screen, you can set the water supply pressure, monitor the equipment operating status and query the equipment fault information at the same time, which greatly improves the automation level of the variable frequency automatic water supply equipment and the ability to monitor field equipment.